VALUES OF THE CS

For civil dwelling with cubing lower than 1000 m.c.
Thermic position and typical location of the dwelling
Cal/h mc 1°C
values of the CS
Values of CST with change of air 1 hour
Wintry
Summer
Hourly change of air
(internal-external) /\ T
Benessere
1
1,5
2
2,5
3
15
20
25
30
35
40
min
max
1 Isolated with large glass-walls
2
2,3
2,6
2,9
3,3
30
40
50
60
70
80
18
22
1 Isolated with normal masonry
1,8
2,1
2,4
2,7
3
27
36
45
54
63
72
14
18
2 Self-heating units
1,7
2
2,3
2,6
2,9
25,5
34
42,5
51
59,5
68
-
-
3 Unit glass-floor
1,6
1,9
2,2
2,5
2,8
24
32
40
48
56
64
17
20
3 Unit normal
1,5
1,8
2,1
2,4
2,7
22,5
30
37,5
45
52,5
60
15
17
3 Ground floor with large glass-wall
1,4
1,7
2
2,3
2,6
21
28
35
42
49
56
14
16
3 Top floor with normal glass-walls
1,3
1,6
1,9
2,2
2,5
19,5
26
32,5
39
45,5
52
12
14
3 Normal ground floor
1,2
1,5
1,8
2,1
2,4
18
24
30
36
42
48
10
12
3 Intermediate floors 4 exposed walls
1,1
1,4
1,7
2
2,3
16,5
22
27,5
33
38,5
44
10
11
3 Intermediate floors 3exposed walls
1
1,3
1,6
1,9
2,2
15
20
25
30
35
40
9
10
3 Intermediate floors 2exposed walls
0,8
1,1
1,4
1,7
2
12
16
20
24
28
32
8
9
1) The locations are considered for completely independent units.
2) The location are considered for lodging in complex with thermostatic and independent functioning.
3) The locations are considered for lodging in complexes with only heating plant with continuous functioning.

 
For rooms with wide cubing.

Hourly change of air

Structure
Specific heating
Value mc.
1.000
5.000
10.000
15.000
20.000
25.000
30.000
35.000
40.000
0,5
A
1,4
1,29
1,16
1,05
0,95
0,87
0,8
0,73
0,69
0,5
B
1,2
1,1
1
0,9
0,82
0,74
0,68
0,62
0,59
0,5
C
1
0,92
0,83
0,75
0,68
0,62
0,57
0,52
0,49
1
A
1,7
1,59
1,46
1,35
1,25
1,17
1,1
1,03
1
1
B
1,5
1,4
1,3
1,2
1,12
1,04
0,98
0,92
0,89
1
C
1,3
1,22
1,13
1,05
0,98
0,92
0,87
0,62
0,79
1,5
A
2
1,89
1,76
1,65
1,55
1,47
1,4
1,33
1,3
1,5
B
1,8
1,7
1,6
1,5
1,42
1,34
1,28
1,22
1,19
1,5
C
1,6
1,52
1,43
1,35
1,28
1,22
1,17
1,12
1,09
2
A
2,3
2,19
2,06
1,95
1,85
1,77
1,7
1,63
1,6
2
B
2,1
2
1,9
1,8
1,72
1,64
1,58
1,52
1,49
2
C
2,9
1,82
1,73
1,65
1,58
1,52
1,47
1,42
1,39
A: Large glass-wall rooms with elevated dispersions
B: Rooms with reduced dispersions
C: Rooms very protect (cinema, etc...)
 

FEA S.r.l. - Industrialiplants and machines - Solar Panels- VAT Number 00182340042

Via Saluzzo, 49 - 12030 SCARNAFIGI (CN) - ITALY - Tel. +39.0175.74.134 - Fax +39.0175.74.639
www.feasrl.com - info@feasrl.com